9300 Servo PLC
Appendix
3.6 Code table
3−139
L
9300 Servo PLC EN 5.1
Code InformationPossible settingsLCDCode Information
SelectionLenze
LCD
C0504
PLC memory: RAM access via codes
More detailed information can be found in chapter
3.6.2, "RAM access via codes".
^ 3−150
C0505
C0506
C0507
C0508
C0509
C0510 ProtAppFlash 0 PLC memory: Write protection of the application FLASH
0 No write protection
1 Write protection
C0517 User menu User menu with up to 32 entries
The numbers of the desired codes are entered under
the subcodes.
The data is input in xxx.yy format
– xxx: Code number
– yy: Subcode for code
There is no check whether the entered code exists.
0.00 {0.01} 7999.00
1 51.00 C0051/0 MCTRL−NACT
2 54.00 C0054/0 Imot
3 56.00 C0056/0 MCTRL−MSET2
4 0.00 Not assigned
5 0.00 Not assigned
6 183.00 C0183/0 Diagnostics
7 168.01 C0168/1 Fail number
8 86.00 C0086/0 Mot type
9 22.00 C0022/0 Imax current
10 0.00 Not assigned
11 11.00 C0011/0 Nmax
12 0.00 Not assigned
13 0.00 Not assigned
14 105.00 C0105/0 QSP Tif
15 0.00 Not assigned
16 70.00 C0070/0 Vp speed CTRL
17 71.00 C0071/0 Tn speed CTRL
18 1500.00 C1500/0
19 2100.00 C2100/0 Time slice
20 2102.00 C2102/0 Task switch
21 2104.00 C2104/0 PLC Autorun
22 0.00
23 2108.00 C2108/0 PLC run/stop
24 0.00 Not assigned
... ... ...
30 0.00 Not assigned
31 94.00 C0094/0 Password
32 3.00 C0003/0 Par save
C0540 Function 2 Digital frequency output DFOUT_IO_DigitalFrequency:
Function
X9 is inhibited if 0, 1, or 2 have been selected.
DFOUT_nIn_v = 0 if 4 or 5 have been selected.
The input signals are buffered electrically.
0 DFOUT_nOut_v as %
1 DFOUT_nOut_v as rpm
2 Incremental encoder simulation + zero pulse
4 X9 is output on X10
5 X8 is output on X10