Lenze E84AYCIB Bedienungsanleitung Seite 41

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 75
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 40
EDS84AYCIB EN 4.0 - 11/2010 L 41
E84AYCIB communication manual (INTERBUS)
Process data transfer
Access to process data / PDO mapping
8 Process data transfer
8.1 Access to process data / PDO mapping
The process data (MCI-PDOs) are transferred via the MCI interface.
A maximum of 16 words is exchanged for each direction.
The process data are accessed via the port blocks LP_MciIn and LP_MciOut. These port
blocks are also referred to as process data channels.
The port block LP_MciIn maps the MCI-PDOs received.
The port block LP_MciOut maps the MCI-PDOs to be transmitted.
The port/function block interconnection of the process data objects (PDO) is made via
the Lenze »Engineer«.
[8-1] External and internal data transfer between the bus system, controller, and application
/3B0FL,Q
"
E&WUOB%
E&WUOB%
Z&WUO
E,QB%
E,QB%
Z,Q
Z,Q
GQ,QBS
/3B0FL2XW
E6WDWHB%
E6WDWHB%
Z6WDWH
E2XWB%
E2XWB%
Z2XW
Z2XW
GQ2XWBS
"
)LHOGEXV

$SSOLFDWLRQ
)%LQWHUFRQQHFWLRQ
&RPPXQLFDWLRQPRGXOH
0&,LQWHUIDFH
Software manual / »Engineer« online help for the Inverter Drive 8400
Here you'll find detailed information on the port /function block interconnection
in the »Engineer« and on port blocks.
Seitenansicht 40
1 2 ... 36 37 38 39 40 41 42 43 44 45 46 ... 74 75

Kommentare zu diesen Handbüchern

Keine Kommentare