E84AYCIB communication manual (INTERBUS)
Parameter data transfer
Supported PMS services
52 L EDS84AYCIB EN 4.0 - 11/2010
9.3.7 Status
The "Status" PMS service provides status information about the controller.
The controller provides the following values:
Status Value Description
Logical status 0 = ready for communication Information about the current operating
mode of the controller with regard to
communication
Physical status 0 = ready for operation (device state
"OPERATION ENABLED")
1 = ready for operation to a limited extent
(all other device states)
Information about the current operating
status of the
controller.
Local Detail 0 Is not supported.