13435743_EDBM301_v14.0 25
13.2 MC3000 DISPLAY
The following describes the possible display congurations for the MC3000 Series drive
when operating as a standard drive (without PID control). Refer to Section 19 - MC3000
PID SETPOINT CONTROL for a complete description of drive operation when using
PID control.
13.2.1 MC3000 DISPLAY IN STOP MODE
When the drive is in the STOP mode, there are three possible displays. The first is the
SPEED display, which looks like this:
STOP > 60.00 HZ
DRIVE
STATUS
SPEED
SETPOINT
SPEED
UNITS
DIRECTION
(FORWARD)
NOTE
Refer to Parameter 31 - UNITS for the SPEED UNITS display options.
Pressing the ENTER key will change the display from the SPEED indication to the %
LOAD indication:
STOP > 0% LOAD
DRIVE
STATUS
PERCENT
LOAD
DIRECTION
(FORWARD)
Pressing the ENTER key again will change the display from the % LOAD indication to
the VAC (motor voltage) indication:
STOP > 0 VAC
DRIVE
STATUS
MOTOR
VOLTAGE
DIRECTION
(FORWARD)
Pressing ENTER again will change the display back to the SPEED indication.