Lenze MC3000 Series Bedienungsanleitung Seite 30

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 84
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 29
26 13435743_EDBM301_v14.0
The following table shows the possible DRIVE STATUS indications that can appear on
the drive display:
DRIVE STATUS TABLE
DISPLAY DESCRIPTION
STOP Drive to STOP mode - No output to motor.
RUN
Drive is in RUN mode and is within + 0.3 Hz of the speed setpoint.
FAULT
Drive has shut down due to a FAULT condition. If the fault condition
has passed, pressing the STOP key will clear the fault and return the
drive to the STOP mode.
LOCK Drive is in FAULT LOCKOUT after ve unsuccessful restart attempts.
BRAKE DC BRAKE is energized.
LIMIT
Drive is in CURRENT LIMIT due to an overloaded motor, or ACCEL
is set too fast.
F DEC Drive is in DECEL FREEZE because DECEL is set too fast.
13.2.2 MC3000 DISPLAY IN RUN MODE
When the drive is in the RUN mode, the default display will look like this:
RUN > 60.00 HZ
DRIVE
STATUS
SPEED
SETPOINT
SPEED
UNITS
DIRECTION
(FORWARD)
As in the STOP mode, the ENTER key can be used to toggle the display from SPEED
to % LOAD to VAC (motor voltage):
RUN > 85% LOAD
DRIVE
STATUS
PERCENT
LOAD
DIRECTION
(FORWARD)