Lenze PLC Designer ApplicationTemplate (PLC Designer R3- Bedienungsanleitung Seite 42

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 177
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 41
Working with the ApplicationTemplate
Mapping the actual machine structure in the »PLC Designer«
42
Lenze · ApplicationTemplate · 1.3 EN - 04/2013
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
3. Allocate unique designations to the slaves inserted
(example: "L_94_HL_ActuatorSpeed").
The names can be selected freely and must …
•only
contain the characters "A ... Z", "a ... z", "0 ... 9", or "_";
•not
start with a digit.
You can enter a name by clicking the element.
Example:
4. Setting the cycle time
The value for the EtherCAT master cycle time has to be defined according to the cycle
time of the quickest task.
The icon in front of the respective device indicates the successful
EtherCAT communication.
Note: The EtherCAT cycle time is to be set to the quickest task cycle time set. In this
ApplicationTemplate, the quickest task cycle time is set to 2 ms, therefore 2000 μs have to
be set here.
Seitenansicht 41
1 2 ... 37 38 39 40 41 42 43 44 45 46 47 ... 176 177

Kommentare zu diesen Handbüchern

Keine Kommentare