Data transfer
DRIVECOM profile parameters
7
Feldbus-Baugruppe 2113 INTERBUS
7.6
7.6.7
L
7.6-40
EDSIBS-1.0-06/2003
Bit Name Meaning
0 Ready to switch
on
Controller status information
0 = Status lower than ”READ Y TO SWITCH ON“
1 = Status at least ”READY TO SWITCH ON“
1 Switched on Controller status information
0 = Status lower than ”SWITCHED ON“
1 = Status at least ”SWITCHED ON“
2 Operation
enabled
Controller status information
0 = Status lower than ”OPERATION ENABLED“
1 = Status ”OPERATION ENABLED“
3 Fault Controller status information
0 = No fault (TRIP))
1 = Fault (TRIP) occured
4 Voltage inhibited Information about the command ”voltage inhibit“ (see chapter 7.6.7.4 ”control word“)
0 = Command active
1 = Command not active
5 Quick stop Information about the command ”quick stop“ (see chapter 7.6.7.4 ”control word“)
0 = Command active
1 = Command not active
6 Switch-on
inhibit
Controller status information
0 = Statu not ”SWITCH-ON INHIBIT
1 = Status ”SWITCH-ON INHIBIT“
7 Warning Collective warning
0=Nowarning
1 = Warning (overtemperature)
8 Meldung Collective message. Automatic setting and resetting of pulse inhibit in the controller status
”OPERATION ENABLED”. Reasons for this can be undervoltage or overvoltage as well as
overcurrent (clamp).
0 = No message
1 = Message (IMP)
9 Remote 82XX, 821X, 822X,
8200 vector:
93XX:
Bus access, depends on Lenze parameter ”operating mode”
(L-C0001):
0 = L-C0001
<> 3 or L-C1911 = 0
1 = L-C0001
= 3 and L-C1911 = 1
0 = L-C1911 = 0
1 = L-C1911 = 1
10 FREE
DRIVECOM:
Setpoint
reached
Status of speed/frequency deviation
0=RFG
on
<> RFG
off
1=RFG
on
=RFG
off
11 Limit value Status of the DRIVECOM speed limitation
0 = Limitation not addressed
1 = Limitation addressed
12 FREE
DRIVECOM:
Reserve
820X, 821X, 822X:
8200 vector, 93XX:
Not assigned
Free. Mapping to bit L-C0150.B14
13 FREE
DRIVECOM:
Reserve
82XX:
8200 vector:
93XX:
Not assigned
Free. Mapping to bit L-C0150.B15
Free. Mapping to bit L-C0150.B3
14 Manufacturer 820X, 821X, 822X:
8200 vector, 93XX:
I
max
(current limit reached)
0 = Current limit not reached
1 = Current limit exceeded
Free. Mapping to bit L-C0150.B2
15 Manufacturer 820X, 821X, 822X:
8200 vector, 93XX:
Q
min
(f
d
f
dQmin
)
0=Q
min
not active
1=Q
min
active
Free. Mapping to bit L-C0150.B5