Commissioning
DRIVECOM compatibility
7
Feldbus-Baugruppe 2113 INTERBUS
7.5
7.5.8
L
7.5-8
EDSIBS-1.0-06/2003
7.5.8 DRIVECOM compatibility
The DRIVECOM profile 21 is a specification of important parameters and unit
performance of several manufacturers. The DRIVECOM profile 21 mainly
describes the unit control and a speed operating mode. In addition to the
DRIVECOM specifications there are further Lenze-specific functions, e.g.
digital-frequency connection or DC injection-brake. These manufacturer-specific
specifications require minor changes in the settings to comply with the desired
DRIVECOM compatibility. In the following, you will find the changes required for
the Lenze controllers.
820X With 820X controllers, parameters can only be set when t he cont rolle r is inhibited.
The controller is inhibited in DRIVECOM status.
”SWITCH-ON INHIBIT
”READY FOR SWITCH ON”
”SWITCHED ON”
”TRIP”
821X,
8200 v ector
and 822X
The automatic DC-injection brake must be deactivated in all parameter sets, i. e.
L - C0106=0
L - C2106=0
L - C4106=0 (only 8200 vector)
L - C6106=0 (only 8200 vector)
If the automatic DC-injection brake is not deactivated (holding time o f the DC-injection brake L- C0106
not 0), the controller automatically switches from the status ”OPERATION ENA BLED to the status
”SWITCHED ON when the speed is 0 and the holding time of the DC-injection brake is elapsed. If the
setpoint is higher than 0, the controller is automatically reset to the status ”OPERA TION ENABLED”.
93XX Set the controller parameters for INTERBUS control, e.g. L-C0005=1013
This configuration corresponds t o the signal configuration 1000 wit h t he following changes:
Setpoint selection with INTERBUS
Unit control with INTERBUS
Output X5.A1 is selected as voltage output for the internal supply of the digital inputs.
Actual values and status signals for INTERBUS
For the detailed description of the signal configuration, see 93XX Manual.
9300 Servo
PLC
The following links must be made in the PLC program.
AIF1_wDctrlCtrl W DCTRL_wAIF1Ctrl
DCTRL_wStat W AIF1_wDctrlStat
Drive PLC It is necessary to use the device control for the DRIVE PLC.