Data transfer
Configuration of the parameter data channel (PCP communication)
7
Feldbus-Baugruppe 2113 INTERBUS
7.6
7.6.8
L
7.6-51
EDSIBS-1.0-06/2003
The PCP service ”Get-OV“ reads the object description for each parameter and
data type.
The PCP service ”Identify“ informs about the controller identification. The
controller returns the following parameters:
Name Value Meaning
Name of the manufacturer ”Lenze“ (as visible string) Company name
Controller name Visible string with 15
characters
Unit name for controller and bus-interface module
Controller version Visible string with 15
characters
Software version of the controller
Controller name
The visible string consists of the following characters:
l Characters 1 to 5: Name of the controller
(4 characters for the controller name plus 1 blank)
l Characters 6 to 10: Name of the fieldbus module
(4 characters for the controller name plus 1 blank)
l Characters 11 to 15: No name
(5 blanks)
If a fieldbus module is not available, the corresponding area will be filled with
blanks.
Example:
8200 vector controller with 2113 fieldbus module: ”8212 2113“
sáëáÄäÉ ëíêáåÖ
`çåíêçääÉê å~ãÉ
_~ëáÅ ìåáí
`çåíêçääÉê å~ãÉ
cáÉäÇÄìë ãçÇìäÉ
_ä~åâ
8212 2113
NS
NN NR
Controller version
The visible string consists of the following characters:
l Characters 1 to 5: software version of the controller:
– 2 characters for the basic version
– 2 characters for the variant
– 1 character for the version of the variant
l Characters 6 to 10: software version of the fieldbus module
– 2 characters for the basic version
– 2 characters for the variant
– 1 character for the version of the variant
l Characters 11 to 15: No name
– 5 blanks
Get-OV44
Identify45
Kommentare zu diesen Handbüchern