Data transfer
Process data signals of Lenze controllers
7
Feldbus-Baugruppe 2113 INTERBUS
7.6
7.6.2
L
7.6-16
EDSIBS-1.0-06/2003
ThefollowingparameterscanbeassignedtothePI-data:
Index Subindex Name
(same in IEC1131)
Explanation Lenze setting:
Index 6000
hex
see
6041 0 DRIVECOM status word PI data word 1 ^ 7.6-39
6044 0 DRIVECOM speed Actual speed [rpm] PI data word 2 ^ 7.6-42
6054 0 DRIVECOM actual
percentage value
Actual speed [%] ^ 7.6-43
5F69 0 Device status word
(AIF1_Stat)
Table below
5CA5 1 AIF1-OUT.W1 AIF word 1
5CA5 2 AIF1-OUT.W2 AIF word 2 PI data word 3
5CA5 3 AIF1-OUT.W3 AIF word 3 PI data word 4
5CA4 0 AIF1-OUT.D1 AIFdoubleword
The assignment of AIF-OUT depends on the signal configuration selected under
L-C0005:
Signal
configuration
(L-C0005)
AIF-OUT.W1 AIF-OUT.W2 AIF-OUT.W3 AIF-
OUT.D1
Speed control
1003
1013
1113
MCTRL-NACT
Actual speed
100%=16383
MCTRL-MSET2
Torque display
100%=16383
MCTRL-NSET2
Speed controller input
100%=16383
not
assigned
Torque control
4003
4013
4113
MCTRL-MSET2
Torque display
100%=16383
MCTRL-NACT
Act. speed in %
100%=16383
MCTRL-NSET2
Speed controller input
100%=16383
not
assigned
DF master
5003
5013
5113
MCTRL-NACT
Actual speed
100%=16383
MCTRL-MSET2
Torque display
100%=16383
MCTRL-NSET2
Speed controller input
100%=16383
not
assigned
DF-slave bus
6003
6013
6113
MCTRL-NACT
Actual speed
100%=16383
MCTRL-PHI-ACT
Actual phase
MCTRL-MSET2
Torque setpoint in %
100%=16383
not
assigned
DF-slave cascade
7003
7013
7113
MCTRL-NACT
Actual speed
100%=16383
MCTRL-PHI-ACT
Actual phase
MCTRL-MSET2
Torque setpoint in %
100%=16383
not
assigned
Not equal to xxx3
(except self
configurations)
MCTRL-NACT
Actual speed
100%=16383
MCTRL-MSET2
Torque display
100%=16383
MCTRL-PHI-ACT
Actual phase
not
assigned
For detailed description of the 93XX signal configuration see the Operating
Instructions for 93XX (only the main configurations: 1000, 4000, 5000, etc.) or the
Manual 93XX.
In the controller, other signals can be assigned to AIF-OUT.W1 to AIF-OUT.W3.
For this, the function-block configuration - described in the Manual 93XX- is used.
The function block AIF-OUT determines the output data of the controller as data
interface for the 2133 fieldbus module.
For more detailed information about the function block AIF-OUT, see the Manual
93XX.
Process data telegram from
drive