Index table
15
Appendix
15.1
L
15.1−7
EDSPM−TXXX−9.0−11/2009
Index ImportantPossible settingsName
SelectionLenze
I1803
h
¿
Index is only available in the modular
system
8.3−3
1 COB−ID used by
TxPDO 4
896 385 {1} 2047 Defining the individual identifiers for
process data object 4
2
Transmission type 255 0 {1} 255 Defining the transmission mode
0 Function deactivated The output data are accepted on sync
telegram transmission.
1 ... 240 Process data transfer after sync no. 1
...
Process data transfer after sync no. 240
The output data are accepted after
transmission of the set number (1 ... 240)
of sync telegrams.
254 Time−controlled process data transfer Only if a cycle time is set in I180x
h
,
subindex 5
255 Event−controlled process data transfer
255 Event−controlled process data transfer with cyclic
overlay
Only if a cycle time is set in I180x
h
,
subindex 5
3 Inhibit time 0 0 {1 ms} 65535 Inhibit time
5 Event time 0 0 {1 ms} 65535 Cycle time
I1804
h
¿
Index is only available in the modular
system
8.3−3
1 COB−ID used by
TxPDO 5
448 385 {1} 2047 Defining the individual identifiers for
process data object 5
2
Transmission type 255 0 {1} 255 Defining the transmission mode
0 Function deactivated The output data are accepted on sync
telegram transmission.
1 ... 240 Process data transfer after sync no. 1
...
Process data transfer after sync no. 240
The output data are accepted after
transmission of the set number (1 ... 240)
of sync telegrams.
254 Time−controlled process data transfer Only if a cycle time is set in I180x
h
,
subindex 5
255 Event−controlled process data transfer
255 Event−controlled process data transfer with cyclic
overlay
Only if a cycle time is set in I180x
h
,
subindex 5
3 Inhibit time 0 0 {1 ms} 65535 Inhibit time
5 Event time 0 0 {1 ms} 65535 Cycle time
I1805
h
¿
Index is only available in the modular
system
8.3−3
1 COB−ID used by
TxPDO 6
704 385 {1} 2047 Defining the individual identifiers for
process data object 6
2
Transmission type 255 0 {1} 255 Defining the transmission mode
0 Function deactivated The output data are accepted on sync
telegram transmission.
1 ... 240 Process data transfer after sync no. 1
...
Process data transfer after sync no. 240
The output data are accepted after
transmission of the set number (1 ... 240)
of sync telegrams.
254 Time−controlled process data transfer Only if a cycle time is set in I180x
h
,
subindex 5
255 Event−controlled process data transfer
255 Event−controlled process data transfer with cyclic
overlay
Only if a cycle time is set in I180x
h
,
subindex 5
3 Inhibit time 0 0 {1 ms} 65535 Inhibit time
5 Event time 0 0 {1 ms} 65535 Cycle time