Configuration
Basic configurations
2.2.5 Operation with position storage (C0005 = 12000)
2−12
l
EDSVS9332K−EXT EN 4.0
Code Description
C0005 = 12000 With this configuration and an absolute feedback system (resolver or Sin/Cos absolute value encoder), the position
values of the motor shaft can be stored when switching off the mains. When the mains is switched on again, the actual
values are compared to the stored values.
Master value
C0425 Encoder constant of the master value
Cam profile data
C1300 ... C1317 The cam profile data are determined by the generation of the profile. Usually, they do not have to be changed
separately.
C1420 Determines the profile to be used when an event input is activated (X5/E1 = LOW).
Contouring error evaluation
C1380/1 and C1380/2 Determine comparison window and hysteresis of the contouring error evaluation.
Adjustment values
C0472/2 Influence of speed precontrol
C0472/3 Influence of torque precontrol
C1477/2 Contouring error limit (in s/units)
C0472/4 Reduction factor for contouring error warning; warning limit = C0472/4 × C1477/2
Profile influence
C1472/1 Stretching/compression of X−axis (100 % = no stretching/compression)
C1476/1 Angle trimming in X−direction
C1477/1 Angle trimming in Y−direction
Position memory
C1430/1, C1430/2 Tolerance window of the comparison functions
C1431 Determination of values to be stored (master and/or actual value)
C1476/16 TOUCH−PROBE position in X−direction
C0472/9 Stretching/compression of Y−axis
C0472/10 Torque limit value