Function library
Function blocks
3.2.95 Shift register (STORE3)
3−299
l
EDSVS9332K−EXT EN 4.0
Name LenzeListCFGDIS formatDISType
STORE3−INIT−POS ph C1723/1 ph C1722/1 3 1000 Value for initialising all memory locations.
The value is accepted via a LOW−HIGH
edge at STORE3−INIT.
STORE3−IN−POS ph C1723/2 ph C1722/2 3 1000 Value for the transfer to the memory
location which has been selected via
STORE3−SEL−IN.
The value is accepted with a LOW−HIGH
edge at STORE3−INIT.
STORE3−SEL−IN a Memory location to which the next value
at STORE3−IN−POS is written.
STORE3−SEL−OUT a Memory location from which the next
value is output at STORE3−PHOUT.
STORE3−INIT−BUSY d Handshake signal
HIGH: initialisation of the memories is
active
STORE3−INIT−RDY d Handshake signal
LOW: initialisation of the memories is
active or STORE3−INIT = LOW
HIGH: initialisation of the memories is
completed
STORE3−PHOUT ph Output of the memory location values
Direct parameter setting of the memory locations
l Via C1726/1 ... C1726/16, you can write values [inc] directly into the memory locations 0 ... 15.
Or you can have the registered values displayed via the codes.
l In code C1727/1 you can directly define a memory location. Save the setting with C0003 = 1.
Then the value at STORE3−IN−POS is written to the defined memory location with a
LOW−HIGH edge at STORE3−LOAD−IN−POS after mains connection.