Function library
Function blocks
3.2.89 Position switch points (SPC)
3−287
l
EDSVS9332K−EXT EN 4.0
Mode 2: Centre with switching range
C1645 = Set 1 (SPC1)
C1655 = Set 1 (SPC2)
SPx-L-IN
SPx-STATx
HIGH
LOW
INx-1
INx-2 INx-2
Fig. 3−234 Centre with switching range
l
INx−1 determines the centre
l INx−2 determines the switching range with centre
3.2.89.2 Hysteresis
This function is only available for FB SPC2.
Purpose
Avoids undefined switching of the output signals (in standstill the drive is exactly on a switching
point).
Function
l The hysteresis is selected under C1658.
The setting is valid for SPC2−STAT1 ... SPC2−STAT8.
Hysteresis
C1658
Hysteresis
C1658
Hysteresis
C1658
Hysteresis
C1658
SP2-STATx
HIGH
LOW
SP2-STATx
HIGH
LOW
INx-1 INx-2
SP2-L-IN
INx-1 INx-2
SP2-L-IN
Positive hysteresis
Negative hysteresis
9300kur093
Fig. 3−235 Hysteresis for positive and negative values