Lenze EVS9332xK Bedienungsanleitung Seite 355

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 386
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 354
Function library
Function blocks
3.2.102 Welding bar control (WELD1)
3−327
l
EDSVS9332K−EXT EN 4.0
3.2.102.4 Weld1 mode: Time (C1446 = 0)
The value at the input WELD1−TIME is interpreted as a time value.
Output of status information
l WELD1−T−ERR = HIGH: The total length and the sum of times of the three sections
WELD1−LEN−C (close), WELD1−TIME (weld) and WELD1−LEN−O (open) do not agree. The
reasons may be as follows:
Wrong profile selection
Line speed too high
In such a case the welding time will be automatically reduced to avoid a disturbance of the motion
sequence.
l WELD1−DIR−ERR = HIGH: A negative master angle is assigned to the input WELD1−XIN.
Remedy:
Invert master angle
Invert direction of rotation of the welding bar drive at the function block CCTRL.
l WELD1−ON = HIGH: Welding phase is active
Seitenansicht 354
1 2 ... 350 351 352 353 354 355 356 357 358 359 360 ... 385 386

Kommentare zu diesen Handbüchern

Keine Kommentare