Lenze · Controller | Parameter setting & programming · Reference Manual · DMS 1.5 EN · 04/2014 · TD17 150
13 Parameter reference
13.2 Basic parameters of the Controllers 3200 C/c300 and p300/p500
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C0134
C0136
C0137
C0138
C0139
C0140
Parameter | Name:
C0134 | WinCE users: User 5 with telnet permissions
Data type: UNSIGNED_8
Index: 24441
d
= 5F79
h
User may use telnet
Setting range (min. value | unit | max. value) Lenze setting
010
Read access Write access CINH PLC-STOP No transfer
Parameter | Name:
C0136 | WinCe users: User name 6
Data type: VISIBLE_STRING
Index: 24439
d
= 5F77
h
Name of the user
Read access Write access CINH PLC-STOP No transfer
Parameter | Name:
C0137 | WinCe users: Password 6
Data type: VISIBLE_STRING
Index: 24438
d
= 5F76
h
Password of the user
Read access Write access CINH PLC-STOP No transfer
Parameter | Name:
C0138 | WinCE users: User 6 with FTP permissions
Data type: UNSIGNED_8
Index: 24437
d
= 5F75
h
User may use FTP
Setting range (min. value | unit | max. value) Lenze setting
010
Read access Write access CINH PLC-STOP No transfer
Parameter | Name:
C0139 | FTP: Permissions user 6
Data type: UNSIGNED_32
Index: 24436
d
= 5F74
h
FTP rights of the user.
Value is bit-coded:
Bit 0 Allow Read
Bit 1 Allow Write
Bit 2 Virtual Roots
Bit 3 Allow Hidden Files
Read access Write access CINH PLC-STOP No transfer
Parameter | Name:
C0140 | FTP: Home user 6
Data type: VISIBLE_STRING
Index: 24435
d
= 5F73
h
Home directory of the user
Read access Write access CINH PLC-STOP No transfer