Lenze · Controller | Parameter setting & programming · Reference Manual · DMS 1.5 EN · 04/2014 · TD17 56
6 Parameter setting using »WebConfig«
6.5 User interface of »WebConfig«
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
6.5.7 Parameters of the communication cards
This area of »WebConfig« displays the parameters of the installed communication cards. The
following communication cards can be used:
• MC-CAN2
• MC-PBM (PROFIBUS master)
• MC-PBS (PROFIBUS slave)
• MC-PND (PROFINET)
A distinction is drawn between:
• Interface parameters,
• Communication card parameters.
A communication card can be equipped with several interfaces, such as the MC-CAN2
communication card.
CAN (MC-CAN2) communication card / CAN interface for Controller c300/p300
( 179)
PROFIBUS and PROFINET communication cards ( 185)
6.5.7.1 CAN communication card (MC-CAN2)
The MC-CAN2 communication card ...
• has two CAN connections/interfaces;
•is not
supported by the Controllers c300/p300.
The Controllers c300/p300 only support the CAN master functionality
.
Note!
The parameters are only visible if the MC-CAN2 communication card is installed. For
each Controller, a maximum of one communication card can be used.
Button Function
MC-CAN2
The MC-CAN2 button displays the parameter list of the MC-CAN2
communication card.
MC-CAN2 interface x
Parameters of the x interface of the MC-CAN2 communication card
The MC-CAN2 Interface x button displays the parameters of the respective
interface (1 or 2) of a MC-CAN2 communication card.
In addition, the button displays which card the respective interface belongs
to.
Detailed information on the parameters of the communication cards can be
found here:
CAN (MC-CAN2) communication card / CAN interface for Controller c300/
p300 ( 179)