Mechanical installation
Mounting
5
26
Lenze ¯ BA_3241C ¯ 4.0
5.3 Mounting
Stop!
Short circuit on the backplane bus contact
The backplane bus signals are forwarded to the adjacent module of the
I/O system 1000 via a contact strip. If electrically conductive material
contacts this contact strip, a short circuit can be caused. Moreover,
touching the contact strip can cause a static discharge.
Possible consequences:
¯ Destruction of the device and/or the modules.
Protective measures:
Plug on the contact cover provided in the scope of supply, ...
¯ on to the side contacts of the last I/O module or
¯ if no module of the I/O system 1000 is added.
1
2
1
0
32xxC_004
Fig. 5−2 Mounting
Pos. Description
A Contact cover
How to mount the Controller:
1. Loosen the locking lever for the DIN rail.
2. Put the Controller on the DIN rail.
3. Shut the locking lever.