Establishing an online connection
Going online
86
Lenze · Engineer · 2.13 EN - 10/2014
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
4. Press OK.
•In the Communication path dialog box, the Device access path column displays the
corresponding device access path (e.g. "IPC:172_31_207_254.CAN.can1.dev1.").
6.2.1.7 Gateway controller -> EtherCAT
The controller offers a gateway function to establish an online connection to a field device via
EtherCAT.
How to configure an online connection to a field device which is connected to the
controller via EtherCAT:
1. Go to the Communication path dialog box and select the entry "Gateway controller ->
EtherCAT" from the Bus connection list field.
2. Press Search/Enter....
•The Gateway controller -> Set up EtherCAT bus dialog box is shown:
3. Enter the IP address of the controller.
•By pressing Ping you can carry out a simple test on whether a device can actually be
reached via the IP address set.
Please note: However, this has not necessarily got to mean that the intended device can
be reached via this IP address!
4. Press OK.
•The Enter IP address dialog box is closed.
•In the Communication path dialog box, the Device access path column displays the
corresponding device access path (e.g. "IPC:172_31_207_254.ECAT.ecat1.dev1001.").