Lenze · Commissioning of Lenze drives · 1.3 EN - 06/2014 145
The L_LCB_LogicControlBasic library
L_LCB_PosToUnit - position value conversion
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
13.27 L_LCB_PosToUnit - position value conversion
This FB converts a position value specified in the internal unit [increments] to a position value in the
real unit of the machine on the basis of the machine parameters transmitted.
Inputs
Outputs
Function library: L_LCB_LogicControlBasic
Runtime software licence: LPC 1x00 MPC 1x00 MPC 2xx0 MPC 3x00
L_LCB_AccToUnit
DINT ⎯ diPosIn_p diAccOut_e4 ⎯ DINT
L_LCB_SetAxisData -
machine parameters
⎯ scAxisData xLimit ⎯ BOOL
xError ⎯ BOOL
eError ⎯ L_LCB_Error
Identifier/data type Information/possible settings
diPosIn_p
DINT
Position in [increments]
scAxisData
L_LCB_SetAxisData -
machine parameters
Machine parameters
Identifier/data type Information/possible settings
diPosOut_e4
DINT
Position in [unit]
Display in "e4" view (fixed point with four decimal positions)
xLimit
BOOL
"Output signal is limited" status
• TRUE: The output signal is limited to the representable value range
±214748.3647
xError
BOOL
"Error" status signal
FALSE Conversion carried out without errors
TRUE Error during the conversion
eError
L_LCB_Error
Error number, error code