7Applications
7.19 Fan
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
7.19 Fan
Fans have the task to move a medium with a specific density against a stationary pressure. The pow-
er (P) that has to be applied pneumatically for this purpose can be calculated by means of the differ-
ential pressure (Δp) and the volume flow (Q).
The required data (efficiency, rated speed) of the fan can be gathered from the fan manufactur-
er's data sheet.
7.19.1 Calculations
For a fan according to the drawing the following applies:
[7-172] Equation 1: Power of the medium
The factor 1000 results from the adaptation to the units.
Power of the fan
With the efficiency of the fan the required power of the fan is calculated:
[7-173] Equation 2: Power of the fan
Note!
When altering the gas temperature, the torque requirement of the application changes.
This is to be taken into account with regard to the safety reserve!
Because of the square-law load characteristic the dimensioning is especially to be
checked with regard to undervoltage! Voltage drops at EMC components and the invert-
er also have to be taken into account!
P
QpΔ
1000
---------------
=
P
Vlt
P
η
Vlt
---------
=
Seitenansicht 176