7Applications
7.2 Basic calculations
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Calculation of the effective torque of the application:
[7-4] Equation 4: Effective torque of the application
7.2.2 Power of the application
Power P of the application in [W] results from multiplying the torque and the angular velocity:
[7-5] Equation 5: Power of the application
The base process power P
cto
of the application in [W] results from multiplying the max. torque and
the max. angular velocity:
[7-6] Equation 6: Base process power of the application
The effective base process power P
rms,cto
of the application in [W] results from multiplying the ef-
fective torque and the max. angular velocity:
[7-7] Equation 7: Effective base process power of the application
PM
sum
ω⋅ M
sum
n
2 π⋅
60
-----------
⋅⋅==