Lenze · E94AYCEP communication module (POWERLINK MN/CN) · Communication Manual · DMS 6.0 EN · 02/2014 · TD17 40
6 Commissioning
6.4 Initial switch-on
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Initial switch-on and diagnosing
1. Switch on the Servo Drive 9400 and check whether it is ready for operation using the
diagnostic LEDs of the communication module.
• Red diagnostic LEDs must not be on.
• The following signalling should be visible:
2. If not already done, load the POWERLINK configuration into the Servo Drive 9400.
3. Repeat steps 1. and 2. for all POWERLINK nodes.
4. Start the POWERLINK network.
The network starts automatically if you set the Managing Node last
.
Otherwise there are two options:
• Switch off the network nodes and switch them on together or
• execute a fault reset at the Managing Node (Node ID = ’240’).
5. Check the POWERLINK network again using the diagnostic LEDs of the communication
module.
The following signalling should be visible:
LED Colour Status Meaning
MS Green On Module Status Module status displays
( 51)
DE - Off Device Error
X211 Green On LED is lit if a connection to the node has been established.
Status displays at the RJ45 sockets (X211, X212)
( 53)
X212 Green On
LED Colour Status Meaning
MS Green On Module Status Module status displays
( 51)
ME - Off Module Error
BE - Off Bus Error
DE - Off Device Error
BS Green On Bus Status Fieldbus status displays
( 52)
X211 Green On LED is lit if a connection to the node has been established.
Status displays at the RJ45 sockets (X211, X212)
( 53)
X212 Green On