11 Parameter reference
11.2 Parameters of the communication module for slot MXI1
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C13041
C13042
C13043
C13044
Parameter | Name:
C13041 | EPL version
Data type: UNSIGNED_8
Index: 11534 = 0x2D0E
EPL index: not available
The code describes the version of the POWERLINK communication profile implemented by the communication
module.
The higher-order nibble describes the major version, the lower order nibble describes the minor version. The
implemented value corresponds to the POWERLINK version 2.0.
Read access Write access CINH PLC-STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT
Parameter | Name:
C13042 | Current EPL device address
Data type: UNSIGNED_8
Index: 11533 = 0x2D0D
EPL index: 0x1F93.0x01
The code displays the currently valid EPL node address (Node ID).
• The node ID must be unequivocal in the EPL network segment.
• See also C13044
.
Display area (min. value | unit | max. value)
1 240
Read access Write access CINH PLC-STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT
Parameter | Name:
C13043 | EPL device address selection
Data type: UNSIGNED_8
Index: 11532 = 0x2D0C
EPL index: 0x1F93.0x02
The code indicates whether the EPL node address (node ID) has been set via DIP switches at the communication
module or via the software.
• 0: Node ID has been set via software (C13044
).
• 1: Node ID has been set via DIP switches at the communication module.
Node address setting
( 36)
Display area (min. value | unit | max. value)
0 1
Read access Write access CINH PLC-STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT
Parameter | Name:
C13044 | EPL device address SW
Data type: UNSIGNED_8
Index: 11531 = 0x2D0B
EPL index: 0x1F93.0x03
This code serves to set the EPL node address (node ID) via the software.
The value "0" (Lenze setting) is not a valid node ID. It serves to activate the setting via the DIP switches.
Node address setting
( 36)
Setting range (min. value | unit | max. value) Lenze setting
1 240 0
Read access Write access CINH PLC-STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT