5 Motor interface
5.2 Select motor control
122
Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
For the V/f control and sensorless vector control the following table helps with the selection of the
correct control type:
Selection of the motor control in C00006
Motor cable
shielded ≤ 50 m
unshielded ≤ 100 m
Motor cable
shielded > 50 m
unshielded > 100 m
recommended optional recommended optional
Single drives
With motor filter 6 / 7 - 6 / 7 -
With constant load 4 6 / 7 6 / 7 -
With extremely alternating loads 4 6 / 7 6 / 7 -
With high starting duty 4 6 / 7 6 / 7 -
Positioning and infeed drives 4 6 / 7 6 / 7 -
Winders/unwinders dancer 6 / 7 - 6 / 7 -
Pump and fan drives * 6 / 7 - 6 / 7 -
Three-phase reluctance motors 6 / 7 - 6 / 7 -
Three-phase sliding rotor motors 6 / 7 - 6 / 7 -
Three-phase AC motors with firmly assigned
voltage/frequency characteristic
6 / 7 - 6 / 7 -
Vertical drive/hoist (up to 55 kW) 6 / 7
(with VCC**)
-6 / 7
(with VCC**)
-
* For this application, we recommend a square-law voltage characteristic (C00950
= "1")
** VCC = voltage vector control
Group drives
Depending on the resulting motor cable length:
Identical motors and loads 4 6 / 7 6 / 7 -
Different motors and/or alternating loads 6 / 7 - 6 / 7 -
Note!
For operation with motor encoder, we recommend to use the servo control!
For operation with motor filter, always use the V/f control!
Kommentare zu diesen Handbüchern