Lenze 9400 Bedienungsanleitung Seite 506

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 954
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 505
11 Basic drive functions
11.11 Limiter
506
Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
11.11.1.1 Interface to the safety module
For the simple connection of the safety module to the application, the transmission of the currently
valid safety requirement(s) is effected in the form of a bit coded control signal via the following
interface:
[11-25] Interface to connect the safety module to the basic function "Limiter"
• It is also possible to make several requirements at the same time via the control signal, e.g.
manual jog with limited increment and limited speed 2.
• If no safety module is connected, the control signal can also be generated by means of a
converter block (FB L_DevSMControlEncoder).
LS_SafetyModuleInterface
SMI_dwControl
LS_Limiter
LIM_dwControl