Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06 823
14 Parameter reference
14.2 Parameter list | C00952
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00952
C00953
Parameter | Name:
C00952 | VFC: Frequency interpol. point n
Data type: INTEGER_32
Index: 23623
d
= 5C47
h
From software version V3.0
V/f control
Setting range (min. value | unit | max. value)
-5000 Hz 5000
Subcodes Lenze setting Info
C00952/1 -50 Hz
C00952/2 -40 Hz
C00952/3 -30 Hz
C00952/4 -20 Hz
C00952/5 -10 Hz
C00952/6 0 Hz
C00952/7 10 Hz
C00952/8 20 Hz
C00952/9 30 Hz
C00952/10 40 Hz
C00952/11 50 Hz
Read access Write access CINH PLC STOP No transfer Scaling factor: 1
Parameter | Name:
C00953 | VFC: Voltage interpol. point n
Data type: INTEGER_32
Index: 23622
d
= 5C46
h
From software version V3.0
V/f control
Setting range (min. value | unit | max. value)
0.00 V 1000.00
Subcodes Lenze setting Info
C00953/1 400.00 V
C00953/2 320.00 V
C00953/3 240.00 V
C00953/4 160.00 V
C00953/5 80.00 V
C00953/6 0.00 V
C00953/7 80.00 V
C00953/8 160.00 V
C00953/9 240.00 V
C00953/10 320.00 V
C00953/11 400.00 V
Read access Write access CINH PLC STOP No transfer Scaling factor: 100