13.7 Error messages of the operating system
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
13.7.3 Short overview (A-Z)
The following table contains all error messages of the controller operating system in alphabetical
order with the preset error response and - if available – the parameter for setting the error response.
Tip!
If you click on the cross-reference in the first column, you get to the detailed description of
the corresponding error response in the following chapter "Cause & possible remedies
".
( 623)
Note!
Error message "Unknown error"
If the "Unknown error xxxx" error message is indicated in the logbook or in C00166
, the
reason for the missing plain text is that the error texts required have not been
downloaded to the controller during the application download.
• This, for instance, is the case if a device module plugged into the controller has not
been included in the Engineer project.
• Remedy: Include the device module, recompile and download the project.
hex dec Error message Response (Lenze setting) can be set in
0x007b003f
8060991 A mains phase has failed Fault -
0x007b001a
8060954 Absolute value encoder: Communication error Fault -
0x00b8000c
12058636 Acceleration has been limited Information C02716/3
0x007b0012 8060946 Actual speed value outside tolerance (C00576) No response C00579
0x007d0000 8192000 Analog input 1: Master current < 4 mA Fault C00598
0x008c000c 9175052 Application and device are incompatible Fault -
0x006a0013
6946835 Application has started Information -
0x006a000e
6946830 Application has stopped Information -
0x006a0014
6946836 Application has stopped Information -
0x006a0004
6946820 ApplicationTask: Overflow Fault C02111
0x00910012 9502738 Block function in wrong MEC task Fault -
0x007b0040
8060992 Brake chopper: Ixt > C00570 Warning C00569
0x007b0041 8060993 Brake resistance: I2t > C00572 Warning C00571
0x007b001d 8060957 Brake resistor: I²xt overload Information -
0x007b001c 8060956 Brake transistor: Ixt overload No response C00573
0x007b0021 8060961 Brake transistor: Overcurrent Fault -
0x006a000f
6946831 Breakpoint reached Information -
0x00b80014
12058644 Cam Data is corrupted Warning locked -
0x00b80016
12058646 Cam Data locked due to wrong password Warning locked -
0x00b80017
12058647 Cam Data locked due to wrong security key Warning locked -
0x00b80015
12058645 Cam Data restored Fault -
0x00b80035
12058677 Cam Data: Invalid product number Information -
0x00b80034
12058676 Cam Data: Invalidated (due to change of mechanical data) Warning -
0x00b80013 12058643 Cam data: serial number MM does not match Warning locked -
0x00a10008
10551304 CAN module (MXI1) PDO manager: Faulty configuration Warning locked -
0x00a10000
10551296 CAN module (MXI1) RPDO1: Telegram not received or faulty No response C13591/1
0x00a10001 10551297 CAN module (MXI1) RPDO2: Telegram not received or faulty No response C13591/2
0x00a10002 10551298 CAN module (MXI1) RPDO3: Telegram not received or faulty No response C13591/3
0x00a10003 10551299 CAN module (MXI1) RPDO4: Telegram not received or faulty No response C13591/4