Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06 785
14 Parameter reference
14.2 Parameter list | C00396
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00396
C00397
C00398
C00399
C00412
Parameter | Name:
C00396 | Service code
Data type: UNSIGNED_32
Index: 24179
d
= 5E73
h
This code is for device-internal use only and must not be written to by the user!
Parameter | Name:
C00397 | Service code
Data type: UNSIGNED_32
Index: 24178
d
= 5E72
h
This code is for device-internal use only and must not be written to by the user!
Parameter | Name:
C00398 | Test mode motor control
Data type: UNSIGNED_32
Index: 24177
d
= 5E71
h
Danger!
When the test mode is activated, the parameterisable error response "Quick stop by trouble" has no effect!
If the test mode is active and a monitoring function responds with this error response, no quick stop is executed but
the motor continues to rotate with the frequency set for the test mode!
Selection list (Lenze setting printed in bold) Info
0 Test mode deactivated
1 U rotation test mode
2 I rotation test mode
3 Current controller optimisation
mode
After controller enable, the motor is supplied with
current as long as the controller is enabled.
4 Current controller optimisation
mode impulse
From software version V7.0
The motor is supplied with voltage for 50 ms after
controller enable. Due to this time limit, the load of the
machine is reduced. Afterwards, the controller is
inhibited automatically.
Read access Write access CINH PLC STOP No transfer Scaling factor: 1
Parameter | Name:
C00399 | Settings for test mode
Data type: INTEGER_32
Index: 24176
d
= 5E70
h
Setting range (min. value | unit | max. value)
-1000.0 Hz/1° 1000.0
Subcodes Lenze setting Info
C00399/1 0.0 Hz/1° Frequency [Hz] for test mode
C00399/2 0.0 Hz/1° Start angle [°] for test mode
Read access Write access CINH PLC STOP No transfer Scaling factor: 10
Parameter | Name:
C00412 | Hiperface: Initialisation time
Data type: UNSIGNED_32
Index: 24163
d
= 5E63
h
From software version V11.0
Parameterisation of a Hiperface encoder with increased initialisation time
Setting range (min. value | unit | max. value) Lenze setting
150 ms 2000 650 ms
Read access Write access CINH PLC STOP No transfer Scaling factor: 1