14 Parameter reference
14.2 Parameter list | C00436
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00436
C00437
Parameter | Name:
C00436 | SSI encoder: partword length
Data type: UNSIGNED_8
Index: 24139
d
= 5E4B
h
From software version V5.0
Use of an SSI encoder at X8
Setting range (min. value | unit | max. value)
031
Subcodes Lenze setting Info
C00436/1 31 SSI enc.: Partword 1 length
C00436/2 0 SSI enc.: Partword 2 length
C00436/3 0 SSI enc.: Partword 3 length
C00436/4 0 SSI enc.: Partword 4 length
C00436/5 0 SSI enc.: Partword 5 length
C00436/6 0 SSI enc.: Partword 6 length
C00436/7 0 SSI enc.: Partword 7 length
C00436/8 0 SSI enc.: Partword 8 length
Read access Write access CINH PLC STOP No transfer Scaling factor: 1
Parameter | Name:
C00437 | SSI encoder: partword data coding
Data type: UNSIGNED_8
Index: 24138
d
= 5E4A
h
From software version V5.0
Use of an SSI encoder at X8
Selection list (Lenze setting printed in bold)
0binary coded
1gray coded
Subcodes Lenze setting Info
C00437/1 0: binary coded SSI enc.: Partword 1 coding
C00437/2 0: binary coded SSI enc.: Partword 2 coding
C00437/3 0: binary coded SSI enc.: Partword 3 coding
C00437/4 0: binary coded SSI enc.: Partword 4 coding
C00437/5 0: binary coded SSI enc.: Partword 5 coding
C00437/6 0: binary coded SSI enc.: Partword 6 coding
C00437/7 0: binary coded SSI enc.: Partword 7 coding
C00437/8 0: binary coded SSI enc.: Partword 8 coding
Read access Write access CINH PLC STOP No transfer Scaling factor: 1