Lenze 9400 Bedienungsanleitung Seite 913

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 954
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 912
Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06 913
14 Parameter reference
14.3 Attribute table
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
14.3 Attribute table
The table of attributes contains information required for a communication with the controller via
parameters.
How to read the table of attributes:
Column Meaning Entry
Code Parameter name Cxxxxx
Name Parameter short text (display text) Text
Type Parameter type Selection list Value from selection list
Bit coded Bit coded value
Linear value Value with setting range
String String
Index dec Index under which the parameter is addressed.
The subindex for array variables corresponds to the
Lenze subcode number.
24575 - Lenze code number Is only required for access via a bus
system.
hex 5FFF
h
- Lenze code number
Data DS Data structure E Single variable
(only one parameter element)
A Array variable
(several parameter elements)
DA Number of array elements (subcodes) Number
DT Data type BITFIELD_8 1 byte bit-coded
BITFIELD_16 2 bytes bit-coded
BITFIELD_32 4 bytes bit-coded
INTEGER_8 1 byte with sign
INTEGER_16 2 bytes with sign
INTEGER_32 4 bytes with sign
UNSIGNED_8 1 byte without sign
UNSIGNED_16 2 bytes without sign
UNSIGNED_32 4 bytes without sign
VISIBLE_STRING [xx] ASCII string (with character length xx)
Factor Factor for data transmission via a bus system,
depending on the number of decimal positions
Factor 1 no decimal positions
10 1 decimal position
100 2 decimal positions
1000 3 decimal positions
10000 4 decimal positions
CINH Writing is only possible if the controller is inhibited CINH
Code Name Type Index Data
dec hex DS DA DT Factor CINH
C00002
Device commands Selection list 24573 5FFD E 1 UNSIGNED_32 1
C00003
Device command status Linear value 24572 5FFC E 1 UNSIGNED_32 1
C00004 Service password Linear value 24571 5FFB E 1 UNSIGNED_32 1
C00005
Application selection Linear value 24570 5FFA E 1 INTEGER_32 1
C00006
Select motor control Selection list 24569 5FF9 E 1 UNSIGNED_32 1 CINH
C00007
Active application Linear value 24568 5FF8 E 1 INTEGER_32 1
C00008 Device command progress Linear value 24567 5FF7 E 1 UNSIGNED_32 1
C00011 Motor reference speed Linear value 24564 5FF4 E 1 UNSIGNED_32 1
C00018
Switching frequency Selection list 24557 5FED E 1 UNSIGNED_32 1
C00019 Threshold - standstill recognition Linear value 24556 5FEC E 1 UNSIGNED_32 1
C00022
Maximum current Linear value 24553 5FE9 E 1 UNSIGNED_32 100
C00034
Config. analog input 1 Selection list 24541 5FDD E 1 UNSIGNED_32 1
C00050 Speed setpoint [rpm] Linear value 24525 5FCD A 2 INTEGER_32 1
C00051 Actual speed [rpm] Linear value 24524 5FCC E 1 INTEGER_32 1
Greyed out = display parameter (read only access)
Seitenansicht 912
1 2 ... 908 909 910 911 912 913 914 915 916 917 918 ... 953 954

Kommentare zu diesen Handbüchern