Lenze ETC Motion Control Bedienungsanleitung Seite 70

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 428
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 69
Getting started
Creating a PLC sample program
Loading the PLC sample program into the control system
2
2.12
2.12.3
l
70
EDSTCXN EN 2.0
4. Double−click the "Address" field and specify the correct IP address.
( 28).
ETCM041
) Note!
Do not use any leading zeros in the IP addresses. Otherwise, the
IP address will be interpreted as octa decimal number.
5. As the control system contains a Motorola processor, the field
"Motorola byteorder" must be set to "Yes". If required, correct this
setting by double−clicking several times.
) Note!
The left window area shows the connection options, in this case
the two connections "local_" and "network".
The current setting is the setting that is displayed in the right
window before you click OK, it is used for log in.
6. Close the window with OK.
Seitenansicht 69
1 2 ... 65 66 67 68 69 70 71 72 73 74 75 ... 427 428

Kommentare zu diesen Handbüchern

ama 11 Jan 2025 | 19:35:39

rasha