Wiring of the standard device
Standard devices with a power of 45 kW
Mains choke/mains filter assignment
5
5.6
5.6.5
5.6−6
EDSVS9332P EN 5.0−07/2013
Supply conditions
Range Description
Fuses l Only according to UL 248
l Mains short−circuit current up to 10000 A
rms
: All classes permissible
l Mains short−circuit current up to 50000 A
rms
: Only classes "J", "T" or "R"
permissible
Cables l Only in accordance with UL
l The cable cross−sections specified in the following apply under the following
conditions:
Conductor temperature < 60 °C
Ambient temperature < 40 °C
Observe all national and regional regulations!
9300 Rated fuse current Cable cross−section
Fuse L1, L2, L3, PE
Type [A] [AWG]
Operation with mains choke/mains filter
EVS9330−xP
100 1
5.6.5 Mains choke/mains filter assignment
9300 Mains choke Interference voltage category according to EN 61800−3 and motor cable length
Component Component
Type C2 max. [m] C1 max. [m]
EVS9330−xP ELN3−0038H085
EZN3A0030H110 25
EZN3B0030H110 50
EZN3A0030H110N001
3)
25
E82ZN55334B230 50
3)
For controllers with thermal separation
Installation to UL
Seitenansicht 121