Configuration
Basic configurations
8
8.5
8.5−77
EDSVS9332P EN 5.0−07/2013
IMPORTANTPossible settingsCode
SelectionLenzeDesignationNo.
C1650
SP2−RESET 1000 FIXED0 ® selection list 2 SP2
Configuraton of digital input
signal
C1651 0
1
...
104
Real zero
VTPOS−No 001
...
VTPOS−No 104
SP2
1 SP2−VALUE 1−1 1
Switching point output
SP2−STAT1
2 SP2−VALUE 1−2 1
3 SP2−VALUE 2−1 1
Switching point output
SP2−STAT2
4 SP2−VALUE 2−2 1
5 SP2−VALUE 3−1 1
Switching point output
SP2−STAT3
6 SP2−VALUE 3−2 1
7 SP2−VALUE 4−1 1
Switching point output
SP2−STAT4
8 SP2−VALUE 4−2 1
9 SP2−VALUE 5−1 1
Switching point output
SP2−STAT5
10 SP2−VALUE 5−2 1
11 SP2−VALUE 6−1 1
Switching point output
SP2−STAT6
12 SP2−VALUE 6−2 1
13 SP2−VALUE 7−1 1
Switching point output
SP2−STAT8
14 SP2−VALUE 7−2 1
15 SP2−VALUE 8−1 1
Switching point output
SP2−STAT8
16 SP2−VALUE 8−2 1
C1652
SP2−L−IN 1000 FIXED0INC ® Selection list 3 SP2
Configuration of input signal
C1653 SP2−RESET ) 0 1 SP2
Display of digital input signal
C1654 SP2−L−IN ) −1073741824 {1 inc} 1073741823 SP2
Display of input signal
C1655 SP2−MODE 0
0 Starting point and final point
SP2
Setting of the switching points
1 Centre with switch range
C1657 −30000 {1 ms} 30000
SP2
Dead time
1 DEAD TIME 0
... ... 0
4 DEAD TIME 0
C1658 HYSTERESIS 0 −32767 {1 inc} 32767 SP2
Hysteresis
C1659 FILTER 1 0
1
2
4
8
16
Filter off
Filter 1 ms
Filter 2 ms
Filter 4 ms
Filter 8 ms
Filter 16 ms
SP2
Filters