Lenze EVS9332xP Bedienungsanleitung Seite 42

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 445
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 41
Technical data
Rated data
Overcurrent operation
3
3.3
3.3.3
3.3−4
EDSVS9332P EN 5.0−07/2013
3.3.3 Overcurrent operation
Under the operating conditions described here, the
EVS9321−xP ... EVS9324−xP controllers can supply a rated output current
which is up to twice as high.
Note!
If you enter values > 1.5 × rated output current under C0022, the
controller switches to overcurrent operation.
ƒ Switching between overcurrent operation and standard
operation is only possible if the controller is inhibited
(X5/28 = LOW).
ƒ The continuous current is automatically reduced to 70 % of
the rated output current.
3.3.3.1 Operation at 400 V
Basis of the data
Voltage Frequency
AC mains connection [V
rate
d
]
3/PE AC 320 V − 0 % ... 440 V + 0 %
45 Hz − 0 % ... 65 Hz + 0 %
DC−mains connection
(alternatively)
[U
DC
] DC 450 V − 0 % ... 620 V + 0 % ˘
Output voltage
With mains choke 3 ~ 0 approx. 94 % V
rated
˘
Without mains choke 3 ~ 0 ... U
N
˘
9300 Mains current
1)
Typical motor power Output power Power loss
With
mains choke
Without
mains choke
ASM
(4−pole)
8 kHz
2)
U, V, W +U
G
, −U
G
3)
Type I
r
[A] I
r
[A] P
r
[kW] P
r
[hp] S
r8
[kVA] P
DC
[kW] P
V
[W]
EVS9321−xP 1.5 2.1 0.37 0.5 1.0 2.0 100
EVS9322−xP 2.5 3.5 0.75 1.0 1.7 0.75 110
EVS9323−xP 3.9 5.5 1.5 2.0 2.7 2.2 140
EVS9324−xP 7.0 ˘ 3.0 4.0 4.8 0.75 200
Bold print = Lenze setting
1)
Mains currents at 8 kHz switching frequency
2)
Switching frequency of the inverter
3)
Power which can additionally be drawn from the DC bus at operation with power−adapted motor
Seitenansicht 41
1 2 ... 37 38 39 40 41 42 43 44 45 46 47 ... 444 445