Configuration
Basic configurations
8
8.5
8.5−26
EDSVS9332P EN 5.0−07/2013
IMPORTANTPossible settingsCode
SelectionLenzeDesignationNo.
C0576 100.00 0.00 {0.01 %} 100.00 nErr monitoring speed window
Setting of the system deviation
between actual speed value
and speed setpoint
C0577 VP FLD WEAK 3.00 0.00 {0.01
ms]
15.99 Field weakening controller
V
p
gain
C0578 TN FLD WEAK 50.0 2.0 {0.5 ms} 8192,0 Field weakening controller
Reset time Tn
C0578 = 8000 ms: Switched off
C0579 MONIT NERR 3 0
1
2
3
TRIP
Message
Warning
Off
nEEr monitoring
Configuration of "system
deviation between actual speed
value and speed setpoint"
monitoring
C0580 MONIT SD8 3 0
3
TRIP
Off
SD8 monitoring
Configuration of "Encoder error
at X8" monitoring
C0581 MONIT EER 0 0
1
2
3
TRIP
Message
Warning
Off
EEr monitoring
Configuration of "external
fault" monitoring
C0582 MONIT OH4 2 2
3
Warning
Off
OH4 monitoring
Configuration of heatsink
temperature monitoring
C0583 MONIT OH3 ® 0
2
3
TRIP
Warning
Off
OH3 monitoring
Configuration of "fixed motor
temperature" monitoring
à Depends on C0086
C0584 MONIT OH7 ® 2
3
Warning
Off
OH7 monitoring
Configuration of "adjustable
motor temperature"
monitoring
à Depends on C0086
Temperature monitoring via
resolver input
C0585 MONIT OH8 3 0
2
3
TRIP
Warning
Off
OH8 monitoring
Configuration of "adjustable
motor temperature"
monitoring
Temperature monitoring via
PTC input
C0586 MONIT SD2 0 0
2
3
TRIP
Warning
Off
SD2 monitoring
Configuration of resolver
monitoring
C0587 MONIT SD3 3 0
2
3
TRIP
Warning
Off
SD3 monitoring
Configuration of "encoder at
X9" monitoring
C0588 MONIT
H10/H11
0 0
2
3
TRIP
Warning
Off
H10/H11 monitoring
Setting C0588 = 2 or C0588 = 3
only allowed for Lenze service
C0589 MONIT P03 2 0
2
3
TRIP
Warning
Off
P03 monitoring
Configuration of following error
monitoring
l The following error is
monitored by the DFSET
function block. The
monitoring is only active if
DFSET is used.