Configuration
Basic configurations
8
8.5
8.5−7
EDSVS9332P EN 5.0−07/2013
IMPORTANTPossible settingsCode
SelectionLenzeDesignationNo.
C0088
MOT CURRENT à 0.2 {0.1 A} 500.0 Rated motor current
à Depends on C0086
l Change of C0086 resets
value to the assigned Lenze
setting
C0089
MOT
FREQUENCY
à 10 {1 Hz} 1000 Rated motor frequency
C0090
MOT VOLTAGE à 50 {1 V} 500 Rated motor voltage
à Depends on C0086
l Change of C0086 resets
value to the assigned Lenze
setting
C0091
MOT COS PHI à 0.50 {0.01} 1.00
Motor cos j
à Depends on C0086
l Change of C0086 resets
value to the assigned Lenze
setting
C0093 DRIVE IDENT ) 0
1
93xx
Defective power section
No power section
93xx
Controller identification
93xx: Lenze position controller
C0094 PASSWORD 0 0 {1} 9999 Password
l Parameter access protection
for the keypad. When the
password is activated, only
codes of the user menu can
be accessed. For further
possible selections see
C0096
C0095
ROTOR POS
ADJ
0 0
1
Not active
Active
Rotor position adjustment
For synchronous motors
l C0058 displays the zero
angle of the rotor
l C0095 = 1 starts position
adjustment
C0096
0
1
2
3
No access protection
Read protection
Write protection
Read/Write protection
Extended password protection
for bus systems with activated
password (C0094)
l All codes in the user menu
can be accessed
1 AIF PROTECT. 0 AIF access protection
2 CAN PROTECT. 0 CAN access protection
C0099 S/W VERSION ) x.xx Software version
C0101 0.000 {0.001 s} 999.900
NSET
Additional acceleration times
for the main setpoint
(relating to speed variation
0 ... n
max
)
See system
manual
(extension)
1 NSET−TIR 0.000
2 NSET−TIR 0.000
... ... ...
15 NSET−TIR 0.000
C0103 0.000 {0.001 s} 999.900
NSET
Additional deceleration times
for the main setpoint
(relating to speed variation
0 ... n
max
)
1 NSET−TIF 0.000
2 NSET−TIF 0.000
... ... ...
15 NSET−TIF 0.000
C0105 QSP TIF 0.000 0.000 {0.001 s} 999.900 Quick stop deceleration time
(QSP)
(relating to speed variation
0 ... n
max
)