Wiring of the standard device
Standard devices in the power range 0.37 ... 11 kW
Important notes
5
5.4
5.4.2
5.4−3
EDSVS9332P EN 5.0−07/2013
5.4.2 Important notes
To gain access to the power connections, remove the covers:
ƒ Release the cover for the mains connection with slight pressure on the
front and pull it off to the top.
ƒ Release the cover for the motor connection with slight pressure on the
front and pull it off to the bottom.
Installation material required from the scope of supply:
Description Use Quantity
Shield connection support Support of the shield sheets for the supply
cable and motor cable
2
Hexagon nut M5
Fastening of shield connection supports
4
Spring washer Æ 5 mm (DIN 127) 2
Serrated lock washer Æ 5.3 mm
(DIN 125)
2
Shield sheet Shield connections for supply cables, motor
cable
2
Screw and washer assembly
M4 × 10 mm (DIN 6900)
Fastening of shield sheets 4