Configuration
Basic configurations
8
8.5
8.5−18
EDSVS9332P EN 5.0−07/2013
IMPORTANTPossible settingsCode
SelectionLenzeDesignationNo.
C0361
)
0.00 {1.00 %} 100.00 CAN
Bus load of system bus
For perfect operation the entire
bus load (all nodes connected)
should be less than 80 %
See system
manual
(extension)
1 LOAD OUT All telegrams sent
2 LOAD IN All telegrams received
3 LOAD OUT1 Telegrams sent on CAN−OUT1
4 LOAD OUT2 Telegrams sent on CAN−OUT2
5 LOAD OUT3 Telegrams sent on CAN−OUT3
6 LOAD POUT1 Telegrams sent on parameter
channel 1
7 LOAD POUT2 Telegrams sent on parameter
channel 2
8 LOAD IN1 Telegrams received from
CAN−IN1
9 LOAD IN2 Telegrams received from
CAN−IN2
10 LOAD IN3 Telegrams received from
CAN−IN3
11 LOAD PIN1 Telegrams received from
parameter channel 1
12 LOAD PIN2 Telegrams received from
parameter channel 2
C0362 SYNC CYCLE 1.0 −32.0 {0.1 ms} 32.0 CAN
Time between two sync
telegrams on the system bus
See system
manual
(extension)
C0363 SYNC CORR 1 1
2
3
4
5
0.8 ms
1.6 ms
2.4 ms
3.2 ms
4.0 ms
CAN
Correction value for C0362
See system
manual
(extension)
C0364
CAN ACTIVE 1000 FIXED0 ® selection list 2 CAN
Configuraton of digital input
signal
l Switches system bus from
"Pre−operational" to
"Operational" via external
signal
See system
manual
(extension)
C0365 CAN ACTIVE ) CAN
System bus status
C0366 SYNC
RESPONSE
1 0
1
No sync response
Sync response
CAN
Response to sync telegram by
master
See system
manual
(extension)
C0367 SYNC RX ID 128 1 {1} 256 CAN
Receive identifier (Rx)
l Sync identifier for grouping
for accepting the data in
CAN−IN1
See system
manual
(extension)
C0368 SYNC TX ID 128 1 {1} 256 CAN
Transmit identifier (Tx)
l Identifier for the generation
of a sync telegram
C0369 SYNC TX TIME 0 0 {1} 65000 CAN
Sync transmission interval (Tx)
l Transmission interval of the
object set under C0368
See system
manual
(extension)
Kommentare zu diesen Handbüchern