Configuration
Basic configurations
8
8.5
8.5−35
EDSVS9332P EN 5.0−07/2013
IMPORTANTPossible settingsCode
SelectionLenzeDesignationNo.
C0780
NSET−N 1000 FIXED0% ® Selection list 1 NSET
Configuration main setpoint
input
See system
manual
(extension)
C0781
NSET−N−INV 1000 FIXED0 ® selection list 2 NSET
Configuration main setpoint
inversion
C0782
NSET−NADD 1000 FIXED0% ® Selection list 1 NSET
Configuration additional
setpoint input
C0783
NSET−NADD−IN
V
1000 FIXED0 ® selection list 2 NSET
Configuration of additional
setpoint inversion
C0784
NSET−CINH−VA
L
1000 FIXED0% ® Selection list 1 NSET
Configuration of output signal
with inhibited controller
C0785
NSET−SET 1000 FIXED0% ® Selection list 1 NSET
Configuration ramp function
generator
See system
manual
(extension)
C0786
NSET−LOAD 1000 FIXED0 ® selection list 2 NSET
Configuration of digital input
(load ramp function generator)
C0787
® selection list 2
NSET
Configuration of JOG selection
and JOG activation
l Binary interpretation
1 NSET−JOG*1 1000 FIXED0
2 NSET−JOG*2 1000 FIXED0
3 NSET−JOG*4 1000 FIXED0
4 NSET−JOG*8 1000 FIXED0
C0788
® selection list 2
NSET
Configuration of Ti selection
and Ti activation
l Binary interpretation
l T
ir
and T
if
are equal
See system
manual
(extension)
1 NSET−TI*1 1000 FIXED0
2 NSET−TI*2 1000 FIXED0
3 NSET−TI*4 1000 FIXED0
4 NSET−TI*8 1000 FIXED0
C0789
NSET−RFG−0 1000 FIXED0 ® selection list 2 NSET
Digital input (ramp function
generator 0)
C0790
NSET−RFG−STO
P
1000 FIXED0 ® selection list 2 NSET
Digital input (ramp function
generator stop)