Configuration
Basic configurations
8
8.5
8.5−17
EDSVS9332P EN 5.0−07/2013
IMPORTANTPossible settingsCode
SelectionLenzeDesignationNo.
C0357 0 {1 ms} 65000 CAN
System bus monitoring times
l After a fault message, the
CAN objects remain in
receive position
See system
manual
(extension)
1 CE1 MONIT
TIME
3000 CAN−IN1
2 CE2 MONIT
TIME
3000 CAN−IN2
3 CE3 MONIT
TIME
3000 CAN−IN3
C0358 RESET NODE 0 0
1
No function
CAN reset
CAN
Establish nodal reset point for
system bus
See system
manual
(extension)
C0359 CAN STATE ) 0
1
2
3
Operational
Pre−operational
Warning
Bus off
CAN
System bus status
See system
manual
(extension)
C0360
)
0 65535 CAN
Telegram counter (number of
telegrams)
Count values > 65535: Restart
with 0
See system
manual
(extension)
1 MESSAGE OUT All telegrams sent
2 MESSAGE IN All telegrams received
3 MESSAGE
OUT1
Telegrams sent on CAN−OUT1
4 MESSAGE
OUT2
Telegrams sent on CAN−OUT2
5 MESSAGE
OUT3
Telegrams sent on CAN−OUT3
6 MESSAGE
POUT1
Telegrams sent on parameter
channel 1
7 MESSAGE
POUT2
Telegrams sent on parameter
channel 2
8 MESSAGE IN1 Telegrams received from
CAN−IN1
9 MESSAGE IN2 Telegrams received from
CAN−IN2
10 MESSAGE IN3 Telegrams received from
CAN−IN3
11 MESSAGE PIN1 Telegrams received from
parameter channel 1
12 MESSAGE PIN2 Telegrams received from
parameter channel 2
Kommentare zu diesen Handbüchern