Configuration
Basic configurations
8
8.5
8.5−31
EDSVS9332P EN 5.0−07/2013
IMPORTANTPossible settingsCode
SelectionLenzeDesignationNo.
C0710 TRANS1−
FUNCTION
0 0
1
2
Rising edge
Falling edge
Both edges
TRANS1
Edge evaluation
l In the case of a
corresponding signal edge at
IN, OUT switches to HIGH
See system
manual
(extension)
C0711 TRANS1−
PULSE T
0.001 0.001 {0.001
s}
60.000 TRANS1
Pulse duration
C0713
TRANS1−IN 1000 FIXED0 ® selection list 2 TRANS1
Configuraton of digital input
signal
C0714 TRANS1−IN ) TRANS1
Display of digital input signal
C0715 TRANS2−
FUNCTION
0 0
1
2
Rising edge
Falling edge
Both edges
TRANS2
Edge evaluation
l In the case of a
corresponding signal edge at
IN, OUT switches to HIGH
See system
manual
(extension)
C0716 TRANS2−
PULSE T
0.001 0.001 {0.001
s}
60.000 TRANS2
Pulse duration
C0718
TRANS2−IN 1000 FIXED0 ® selection list 2 TRANS2
Configuraton of digital input
signal
C0719 TRANS2−IN ) TRANS2
Display of digital input signal
C0720 DIGDEL1−
FUNCTION
2 0
1
2
On delay
Off delay
On/off delay
DIGDEL1
Function selection
See system
manual
(extension)
C0721 DIGDEL1−DELA
Y T
1.000 0.001 {0.001
s}
60.000 DIGDEL1
Setting of the delay time
C0723
DIGDEL1−IN 1000 FIXED0 ® selection list 2 DIGDEL1
Configuraton of digital input
signal
C0724 DIGDEL1−IN ) DIGDEL1
Display of digital input signal
C0725 DIGDEL2−INFU
NCTION
2 0
1
2
On delay
Off delay
On/off delay
DIGDEL2
Function selection
See system
manual
(extension)
C0726 DIGDEL2−DELA
Y T
1.000 0.001 {0.001
s}
60.000 DIGDEL2
Setting of the delay time
C0728
DIGDEL2−IN 1000 FIXED0 ® selection list 2 DIGDEL2
Configuraton of digital input
signal
C0729 DIGDEL2−IN ) DIGDEL2
Display of digital input signal
C0730 OSZ MODUS 0 0
1
Start measurement
Stop measurement
OSC
Start / stop of the measured
value recording
See system
manual
(extension)
C0731 OSC STATUS 0 0
1
2
3
4
5
Measurement completed
Measurement active
Trigger detected
Abort
Abort after trigger
Read memory
OSC
Current operating status