Technical data
Current characteristics
3
3.4
3.4−1
EDSVS9332P EN 5.0−07/2013
3.4 Current characteristics
The maximum output current of the EVS9326 ... EVS9332 devices is limited
under certain operating conditions:
ƒ At output frequencies f
out
< |5 Hz| and heatsink temperatures
J
K
> 40° C.
ƒ The current limitation depends on the switching frequency.
00
0055
fout [Hz] fout [Hz]
K
<40°C
K
=80°C
01
I
OUT
I
OUT
I
max
I
max
I
0max
I
0max
9300vec132
Fig. 3.4−1 Current derating characteristics
Operation at switching frequency f
chop
= 8 kHz (C0018 = 1)
The current limitation follows the characteristic curve
At output frequencies f
out
< |5 Hz| and heatsink temperatures
J
K
= 40 ... 80 °C, the current limit is steplessly adjusted in the range
Operation at switching frequency f
chop
= 16 kHz (C0018 = 2)
The current limitation follows the characteristic curve and is independent of
the heatsink temperature
At automatic change−over of the switching frequency (C0018 = 0), the controller
operates at f
chop
= 16 kHz. The current limitation follows the characteristic
curve .
If an increased torque is required (e.g. acceleration processes), the controller
automatically switches over to f
chop
= 8 kHz. The current limitation follows the
characteristic curve .
9300
I
0max
[A]
1)
I
0max
[A]
2)
f
chop
= 8 kHz f
chop
= 16 kHz
U
mains
U
mains
400 V 480 V 400 V 480 V
EVS9326−xP 23.5 22.3 15.3 14.5
EVS9327−xP 32.0 30.4 20.8 19.2
EVS9328−xP 47.0 44.7 30.6 28.2
EVS9329−xP 52.0 49.0 33.0 25.0
EVS9330−xP 80.0 72.0 45.0 36.0
EVS9331−xP 110 105 70.0 58.0
EVS9332−xP 126 111 72.0 58.0
1)
Maximum available output current at an output frequency f
out
= |0 Hz| and heatsink temperature
J
K
= 80 °C
2)
Maximum available output current at an output frequency f
out
= |0 Hz|
Kommentare zu diesen Handbüchern