Configuration
Basic configurations
8
8.5
8.5−10
EDSVS9332P EN 5.0−07/2013
IMPORTANTPossible settingsCode
SelectionLenzeDesignationNo.
C0150 STATUS WORD ) 0 {1} 65535 Status word
Display when linked with
automation interfaces
l Binary interpretation
indicates the bit states
See system
manual
(extension)
C0151 FDO (DW) ) Hexadecimal display of the free
digital output signals
configured in C0116
l Binary interpretation
indicates the bit states
See system
manual
(extension)
C0155 STATUS WORD
2
)
Bit00 Fail Bit08 R/L
Status word 2
Extended status word (decimal)
l Binary interpretation
indicates the bit states
Bit01 Mmax Bit09 —
Bit02
Imax Bit10 —
Bit03
IMP Bit11 —
Bit04
RDY Bit12 —
Bit05 CINH Bit13 —
Bit06
TRIP Bit14 —
Bit07 Init Bit15 —
C0156
® selection list 2
Configuration of user−definable
bits of the status word
See system
manual
(extension)
1 STAT.B0 1000 FIXED0
2 STAT.B2 30012 pos−ref−ok
3 STAT.B3 1000 FIXED0
4 STAT.B4 10600 NOT1−OUT
5 STAT.B5 30013 POS−IN−TARGET
6 STAT.B14 15004 DCTRL−FAIL−QSP
7 STAT.B15 500 DCTRL−RDY
C0157
) Display of the freely definable
bits of the status word
See system
manual
(extension)
1 (C0156/1)
... ...
7 (C0156/7)
C0161 ACT TRIP ) Fault messages TRIP error message
Display of the current TRIP fault
message (see also C0168/1)
C0167 RESET
FAILMEM
0 0
1
No reset
Reset
History buffer reset
Clears the history buffer
C0168 )
Fault messages
Fault memory − number
List of faults occurred
1 FAIL NO. ACT Currently active fault
2 FAIL NO. OLD1 Last fault
... ... ...
8 FAIL NO. OLD7 Seventh to last fault
C0169
) Power−on time
Fault memory − time
List of the times when the
faults occurred in C0168
(relating to C0179)
1 FAILTIME ACT Currently active fault
2 FAILTIME OLD1 Last fault
... ... ...
8 FAILTIME OLD7 Seventh to last fault
Kommentare zu diesen Handbüchern