Lenze EVS9332xP Bedienungsanleitung Seite 73

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 445
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 72
Wiring of the standard device
Important notes
Protection of persons
5
5.1
5.1.1
5.1−1
EDSVS9332P EN 5.0−07/2013
5.1 Important notes
Stop!
The drive controller contains electrostatically sensitive
components.
The personnel must be free of electrostatic charge when carrying
out assembly and service operations.
5.1.1 Protection of persons
Danger!
Before working on the controller, check that all power terminals
are deenergised:
ƒ The power terminals U, V, W, +U
G
and −U
G
remain live for at
least 3 minutes after disconnection from the mains.
ƒ The power terminals L1, L2, L3, U, V, W, +U
G
and −U
G
remain
live when the motor is stopped.
Connect or disconnect all pluggable terminals only in the deenergised state!
Pluggable terminal strips
Seitenansicht 72
1 2 ... 68 69 70 71 72 73 74 75 76 77 78 ... 444 445

Kommentare zu diesen Handbüchern

Keine Kommentare