Commissioning
Travel profile parameters
Entering parameters
6
6.11
6.11.3
6.11−6
EDSVS9332P EN 5.0−07/2013
The following chart shows the processing of a program set (PS).
yes
Waiting
active?
Input signal (PFI)
released?
Switching
active?
"Switching before pos."
Will output PFO xx be set?
PS mode
active?
Positioning completed?
Switching
active?
Waiting
time
active?
VTTIME no xx
elapsed?
Branch 1
active?
Input signal (PFI)
released?
"if PS−CANCEL or no TP" select PS
(jump to)
In the field "Jump to"
select PS
Branch 2
active?
Input signal (PFI)
released?
Pce.
number
active?
VTPCS no xx
reached?
Jump
to PS?
Program end
Select
mode
"Switching before pos."
Will output PFO xx be set?
In the field "Jump to"
select PS
In the field "Jump to"
select PS
In the field "Jump to"
select PS
1
1
yes
no
no
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
no
no
no
no
no
no
no
no
no
no
no
no
Fig. 6.11−6 Processing of a program set
Processing a program set